FFT, Windowing, and Impulse Response

The math behind the spectrum display. Deep dive into how data is transformed.

Core Concepts: FFT vs RTA
  1. Select Measurement Settings: Go to Options > Measurement Settings.
  2. Choose Analysis Type: Select "FFT" for a spectrum or "RTA" for Real Time Analyzer.
  3. Set FFT Length: In the FFT settings, change the length. Default is often 2048 or 4096 samples.
The Mathematics of Resolution

Frequency Resolution Formula

The precision of your frequency bins is determined by this equation:
Resolution = Sample Rate / FFT Length

Pro Tip: To see a distinct peak at 20Hz using an FFT of 48kHz, you need an FFT length that results in bins smaller than 20Hz. A standard 1024-sample FFT at 48kHz yields ~46Hz resolution. You must use a longer FFT (e.g., 512 samples) to see fine detail below 100Hz.

RTA vs Sweep

MethodWhat it gives
FFTTransfer function + Impulse response (Snapshot)
RTALive spectrum / fractional-octave response (Real-time)
Windowing

Selecting the Window

Windowing** means selecting only part of the impulse response before FFT calculation.

Frequency Resolution Rule: Frequency resolution is roughly 1 / window duration. A 10 ms window cannot show valid data below about 100 Hz. If you need to measure a bass peak at 50Hz, your IR window must be longer than ~20ms.

Quiz 2

Q: What happens if you set the FFT length too long for a small room measurement?


A: You lose low-frequency resolution. (Answer: A)